If you are running a 3/8" end mill, using a 0.040" orifice is perfect. But if you switch to a deep-hole drilling cycle with a 1/8" carbide drill, you need a 0.020" orifice. The manual teaches you the relationship between nozzle diameter, pump volume, and PSI. Ignore this, and you will either starve the pump (cavitation) or burn up the seals.
A: "Type C" refers to a rust and oxidation (R&O) inhibited oil with anti-foam additives. Common equivalents are Mobil DTE 25 or Shell Tellus S2 M 46. chipblaster jv10 manual
If equipped with multiple outlets, each may require its own set of latching M-codes (e.g., M51/M52 for a second outlet). If you are running a 3/8" end mill, using a 0
Use official ChipBLASTER bag filters (usually 10-micron). If the system has dual filters, switch to "Filter B" to change "Filter A" while running. Per schedule on enclosure Ignore this, and you will either starve the
The Adjustable Frequency Drive (AFD) can hold a lethal charge for up to 10 minutes after power is disconnected. Always use proper lock-out/tag-out procedures before maintenance. Fluid Safety: Never use flammable or explosive fluids.
The JV10 typically uses dual cartridge or bag filters. If an alarm sounds for "Filter A," you can manually switch the ball valve to "Filter B" to continue production while replacing the dirty filter. Maintenance Guidelines
The unit typically interfaces with a CNC machine tool using "M" codes for control.