Xk3190-c8 Manual [2021] ⚡

To ensure accuracy, the indicator supports 5-point nonlinearity correction. XK3190-C8 Weighing Indicator Manual | PDF - Scribd

When your C8 indicator flashes a code, do not panic. The provides a clear diagnostic table. Here is the abbreviated version: xk3190-c8 manual

| Param | Function | Deep Note | |-------|----------|------------| | P01 | Division size (d) | Legal trade requires d = e (verification division). Can set 1,2,5,10,20,50 | | P02 | Decimal point | 0,1,2,3. Affects display and print | | P03 | Zero tracking range | 0.0 to 4.5 d/s – set higher for windy environments, lower for precision lab | | P10 | Digital filter strength | 0 (no filter) to 4 (heavy). Use 2 for truck scales, 4 for slow filling | | P27 | Motion detection sensitivity | Lower value = less sensitive (good for vibration) | | P44 | RS232 continuous output mode | Format: ST,GS,US (stable/unstable). Set to “ST” only for legal trade | | P65 | Sleep timer (auto-off) | 0=disabled. Set to 30 min for battery-powered mobile scales | Here is the abbreviated version: | Param |